Lennox International Inc. 15CHAX User Manual

Browse online or download User Manual for Fireplaces Lennox International Inc. 15CHAX. Lennox International Inc. 15CHAX User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
01/08
*2P0108*
Page 1
505,201M
*P505201M*
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
2006 Lennox Industries Inc.
Dallas, Texas, USA
Table of Contents
Shipping & Packing List 1. . . . . . . . . . . . . . . . . . . . . . . . .
Unit Dimensions 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Arrangement 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Requirements 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Location Selection 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rigging & Setting Unit 4. . . . . . . . . . . . . . . . . . . . . . . . . .
Clearances 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Existing Common Vent Systems 5. . . . . . . . . . . . . . . . .
Condensate Drain 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Filters 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply & Return Connections 6. . . . . . . . . . . . . . . . . . . .
Compressors 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Control Board 9. . . . . . . . . . . . . . . . . . . . . . . . . . .
System Operation Monitor 11. . . . . . . . . . . . . . . . . . . . . .
Unit Start−Up and Operation 13. . . . . . . . . . . . . . . . . . . .
Condenser Fan Clearances 14. . . . . . . . . . . . . . . . . . . . .
Maintenance 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION
INSTRUCTIONS
15CHAX SERIES UNITS
PACKAGED ELECTRIC UNIT (2−5 TONS)
505,201M (38152A082)
01/08
Supersedes 05/06
Shipping & Packing List
1 − Assembled packaged electric unit
As soon as the unit is received, it should be inspected for
possible damage during transit. If you find any damage, im-
mediately contact the last carrier.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent) or service agency.
WARNING
If this unit is to be installed in a mobile or manufac-
tured home application, the duct system must be
sized to achieve static pressures within the
manufacturer’s guidelines. All other installation
guidelines must also be followed. Failure to do so
may result in equipment damage, personal injury
and improper unit performance.
CAUTION
Danger of sharp metallic edges. Can cause injury.
Take care when servicing unit to avoid accidental
contact with sharp edges.
WARNING
Electric shock hazard. Can cause injury
or death. Before attempting to perform
any service or maintenance, turn the
electrical power to unit OFF at
disconnect switch(es). Unit may have
multiple power supplies.
Litho U.S.A.
Page view 0
1 2 3 4 5 6 ... 13 14

Summary of Contents

Page 1 - INSTRUCTIONS

01/08*2P0108*Page 1505,201M*P505201M*RETAIN THESE INSTRUCTIONSFOR FUTURE REFERENCE 2006 Lennox Industries Inc.Dallas, Texas, USATable of ContentsShip

Page 2

Page 10COOLThe COOL jumper is used to determine the CFM duringcooling operation. This jumper selection is activated forcooling when Y1 is energized.Th

Page 3

Page 11System Operation Monitor (LSOM)The system operation monitor (A132) detects the mostcommon fault conditions in the air conditioning system.When

Page 4 - Location Selection

Page 12Table 5System Operation Monitor LED Troubleshooting CodesStatus LED Condition Status LED Description Status LED Troubleshooting InformationGree

Page 5 - Condensate Drain

Page 13Unit Start−Up and OperationEach 15CHAX packaged cooling unit is factory−chargedwith R−410A refrigerant. The compressor is hermeticallysealed, i

Page 6 - Electrical

Page 14Condenser Fan ClearancesThe top of the condenser fan should be 1−1/2 inches fromthe bottom of the top grille. This dimension should bechecked a

Page 7 - Figure 6

HORIZONTALSUPPLY AIROPENINGBACK VIEWEND VIEWTOP VIEWABFRONT VIEWHORIZONTALRETURNAIROPENINGS(2)CLFGHJKDEEDDOWN−FLOWSUPPLY AIROPENINGDOWNFLOWRETURN AIRO

Page 8 - Typical Wiring Diagram

Page 3Parts ArrangementGeneralThese installation instructions are intended as a generalguide only, for use by an experienced, licensed contractor(or e

Page 9 - Blower Control Board (A54)

Page 4  For installation on combustible material.WARNINGProduct contains fiberglass wool.Disturbing the insulation in this product duringinstallati

Page 10 - DEHUMIDIFICATION

Page 5Existing Common Vent SystemsThe 15CHAX packaged cooling units with auxiliary electricheat may replace an existing furnace which is being re-move

Page 11 - IMPORTANT

Page 6FiltersFilters are not factory−supplied with the unit; however,optional internally installed filter kits are available. Filter kit92M54 is used

Page 12

Page 7Unit must be electrically grounded in accordance with localcodes or in the absence of local codes with the NationalElectric Code, ANSI/NFPA No.

Page 13 - Unit Start−Up and Operation

Page 8Figure 715CHAX Series Packaged Electric UnitsTypical Wiring Diagram

Page 14 - Maintenance

Page 9Blower Control Board (A54)Electric shock hazard. Can cause injury ordeath. Before attempting to perform anyservice or maintenance, turn the elec

Comments to this Manuals

No comments